You have got to be pulling our legs! I've heard of some safety-defying demos,
but this one takes the cake!

Perhaps there's some misconception about GFIs. Those letters stand for
"ground fault interrupter". The purpose is to detect an (unwanted and
potentially lethal) fault to ground and to interrupt it quickly. The device
is NOT designed to protect against short circuits; the normal circuit breaker
or fuse is there for that purpose. If ONE side of the circuit (the "hot"
side, that is) were to be faulted to ground, possibly via a human being, then
the GFI would trip the circuit due to the extra current flowing in that leg.
Of course, in an ideal circuit, the "cold" side could be faulted to ground
with no problem. Indeed, the electric code is designed to try to keep that
side of the circuit at ground potential -- hence the requirement for
polarized plugs (wide and narrow blades). It is the imbalance of currents in
the "hot" and "cold" legs that causes the trip to occur.